Environmental And Remedial Treatments For Hydrocarbons

 
Electrocoagulation

ELECTROCOAGULATION

Electrocoagulation has reduced contaminated water volume by 98%; and lowered the treatment cost by  90% for bilge water containing heavy metals and oil emulsions

(Gilmore 1993)

 The electrocoagulation process marketed by E.A.R.T.H. Company Limited. is based on valid scientific principles involving responses of water contaminants to strong electric fields and electrically induced oxidation and reduction reactions. This process is able to take out over 99 percent of some heavy metal cations and also appears to be able to electrocute microorganisms in the water. It is also able to precipitate charged colloids and remove significant amounts  of other ions, colloids, and emulsions. When the system is in place, the  operating costs including electric power, replacement of electrodes, pump maintenance, and labor can be less than $1 per thousand gallons for some applications.  Potential applications to agriculture and quality of rural life  include removal of pathogens and heavy metals from drinking water and decontamination of food processing wash waters.

 

Key Benefits:

  • The reduction of bacteria from 110,000,000 (standard plate count)  in sewage waste water to 2,700 bacteria per milliliter;
  • Can Be Used To Treat The contaminants in oily waste waters from steam  cleaning operations, refineries, rendering plants, and food processors are  generally reduced 95 to 99%;
  • Dissolved silica, clays, carbon black, and other suspended materials in  water are generally reduced by 98%;
  • Heavy metals in water such as arsenic, cadmium, chromium, lead, nickel,  and zinc are generally reduced by 95 to 99%.

 

The following well documented lab and field tested results are routinely attained through electrocoagulation. To determine these parameters Hach DR 4000 method was used. These ranges were determined using USEPA and NIST standards.

 

 

 

 

 

OPERATION

 

 

 

% REMOVED

BOD

 

 

 

90% +

TSS (Clay, coal, silt, etc.)

 

 

99% +

Fats, Oil, Grease in Water

 

 

93 to 99% +

Water in sludges

 

 

 

50 to 80% +

Heavy metal Removal

 

 

 

95 to 99% +

Phosphate Removal

 

 

 

93% +

Bacteria, Viruses, Coliforms,

pathogens & cysts

 

 

 

99.99% +

 

 

 

 

 

 

SPECIFIC EXAMPLES

 

 

 

 

 

 

CONTAMINANT

SOURCE

RAW mg/l

TREATED

% REMOVAL

 

 

 

 

 

Aluminum

Can Mfg.

224

0.693

99.7%

Arsenic

Steam Cleaner

0.30

<0.01

96.7% +

Barium

Steam Cleaner

8.0

<0.10

98.7% +

Calcium

Cooling Tower

1,321

21.4

98.4%

Cadmium

Electroplating

31

0.338

98.9%

Chromium total

Condenser wash

139

<0.1

99.9%

Cobalt

Steam Cleaner

0.13

<0.05

62% +

Copper

Electroplating

287

0.484

99.8%

Iron

Acid Mine

151

0.57

99.6%

Lead

Manufacturing

8.21

0.23

97.2%

Magnesium

Ammunition Plt

6.7

<0.1

98.5%

Manganese

Ammunition Plt

0.28

0.047

83.2%

Mercury

Steam Cleaner

0.006

<0.002

66.6% +

Molybdenum

Steam Cleaner

0.18

0.035

80.6%

Nickel

Manufacturing

185

0.2

99.9%

Silicon

Acid Mine

21.7

0.1

99.5%

Vanadium

Steam Cleaner

0.23

<0.01

95.6% +

Zinc

Plating

221

0.14

99.9%

BOD

Fish Process

40,500

750

98.1%

TSS

Municipal POTW

5,620

25

99.6%

Fog

Food Process

18,165

28

99.9% +

Bacteria

Municipal POTW

110 MM

2,200

99.999% +

For more information or to schedule a complimentary consultation , please contact us either via email at info@earthtt.com. You may also call us at 868-653-7576, 868-653-7571 from . 

We look forward to serving you

 

[Home] [About Us] [Products] [Services] [Incineration] [Electrocoagulation] [Oil Spill Contingency] [Composting] [Waste Management] [Circle Technical Services] [Case Studies]

This Site was Created and Is Maintained by Darron Lord